Combination Stirring Hotplates
- (29)
- (3)
- (85)
- (39)
- (2)
- (7)
- (17)
- (1)
- (2)
- (8)
- (16)
- (7)
- (1)
- (1)
- (4)
- (2)
- (1)
- (23)
- (5)
- (15)
- (3)
- (1)
- (2)
- (8)
- (4)
- (9)
- (1)
- (1)
- (2)
- (9)
- (1)
- (8)
- (1)
- (5)
- (3)
- (14)
- (26)
- (1)
- (18)
- (2)
- (2)
- (2)
- (2)
- (4)
- (1)
- (1)
- (2)
- (10)
- (7)
- (2)
- (14)
- (1)
- (7)
- (1)
- (4)
- (3)
- (11)
- (6)
- (5)
- (1)
- (3)
- (5)
- (8)
- (1)
- (2)
- (9)
- (1)
- (5)
- (1)
- (2)
- (2)
- (6)
- (2)
- (6)
- (2)
- (1)
- (1)
- (1)
- (9)
- (4)
- (3)
- (1)
- (2)
- (13)
- (11)
- (1)
- (2)
- (8)
- (24)
- (1)
- (4)
- (51)
- (74)
- (27)
- (1)
- (2)
- (4)
- (2)
- (34)
- (58)
- (150)
- (7)
Filtered Search Results

PACKAGING CORPORATION OF AMERICA BROWN BOXES HSC. BPT.FLP16X8X6
NC2950916 BROWN BOXES HSC. BPT.FLP16X8X6

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biosurface Technologies Corp CBR W/ 220 STIR/HOT PLATE
The CDC Biofilm Reactor® consists of eight (8) polypropylene coupon holder rods suspended from a UHMW-polyethylene ported lid. Each coupon holder rod can accommodate three (3) 1/2-inch (12.7 mm) diameter coupons, for a total of twenty-four(24) coupons. The lid (with coupon holders and coupons) is mounted in a 1-liter glass vessel with side-arm discharge port. A liquid growth media or biocide is circulated through the vessel while mixing and shear is generated by a magnetic stir bar and vane rotated by a magnetic stir plate.Sampling of the coupons is conducted by aseptically removing individual coupon holder rods with accompanying coupons (3). The coupon holder (or blank) rod is replaced in the lid after sampling to allow the time-course experiment to continue. The coupon removed from the reactor vessel is then used for treatment evaluations, scraped or vortexed to collect the biofilm sample for further study.ĉĉĉĉĉĉĉĉĉĉCDC Biofilm Reactor with 220V Stir/Hot Plate, Mid- to High-Shear Laboratory Biofilm Growth Device, BioSurface Technologies Corporation.ĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉ02-Apr-25 08:00:59:000 PMĉ

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biosurface Technologies Corp AN. CBR W/ STIR/HOT PLATE
The CDC Biofilm Reactor® consists of eight (8) polypropylene coupon holder rods suspended from a UHMW-polyethylene ported lid. Each coupon holder rod can accommodate three (3) 1/2-inch (12.7 mm) diameter coupons, for a total of twenty-four(24) coupons. The lid (with coupon holders and coupons) is mounted in a 1-liter glass vessel with side-arm discharge port. A liquid growth media or biocide is circulated through the vessel while mixing and shear is generated by a magnetic stir bar and vane rotated by a magnetic stir plate.Sampling of the coupons is conducted by aseptically removing individual coupon holder rods with accompanying coupons (3). The coupon holder (or blank) rod is replaced in the lid after sampling to allow the time-course experiment to continue. The coupon removed from the reactor vessel is then used for treatment evaluations, scraped or vortexed to collect the biofilm sample for further study.ĉĉĉĉĉĉĉĉĉĉAnaerobic CDC Biofilm Reactor with Stir/Hot Plate, Mid- to High-Shear Laboratory Biofilm Growth Device, BioSurface Technologies Corporation.ĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉ02-Apr-25 08:00:59:000 PMĉ

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biosurface Technologies Corp CBR W/ STIR/HOT PLATE
The CDC Biofilm Reactor® consists of eight (8) polypropylene coupon holder rods suspended from a UHMW-polyethylene ported lid. Each coupon holder rod can accommodate three (3) 1/2-inch (12.7 mm) diameter coupons, for a total of twenty-four(24) coupons. The lid (with coupon holders and coupons) is mounted in a 1-liter glass vessel with side-arm discharge port. A liquid growth media or biocide is circulated through the vessel while mixing and shear is generated by a magnetic stir bar and vane rotated by a magnetic stir plate.Sampling of the coupons is conducted by aseptically removing individual coupon holder rods with accompanying coupons (3). The coupon holder (or blank) rod is replaced in the lid after sampling to allow the time-course experiment to continue. The coupon removed from the reactor vessel is then used for treatment evaluations, scraped or vortexed to collect the biofilm sample for further study.ĉĉĉĉĉĉĉĉĉĉCDC Biofilm Reactor with Stir/Hot Plate, Mid- to High-Shear Laboratory Biofilm Growth Device, BioSurface Technologies Corporation.ĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉĉ02-Apr-25 08:00:59:000 PMĉ

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
CRYSTAL TECHNOLOGY AND INDUSTRIES HOTPLA STIRRER 10 POS 500ML
NC3762092 HOTPLA STIRRER 10 POS 500ML

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
INDUSTRIAL TEST SYSTEMS INC SULFATE CHECK TEST 100 USD MIN
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
NC3234144 SULFATE CHECK TEST 100 USD MIN

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Molecular Devices MEMBRANE POTENTIAL ASSAY KIT FLIPR 96 WL
MEMBRANE POTENTIAL ASSAY KIT FLIPR 96 WL

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Andwin Scientific 12X12 CERAMIC HOTPLATE 115V EA
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
The 115V hot plate features a 12x12 corrosion-resistant ceramic top ideal for high temperature applications housed in an aluminum frame for cooler edges. It also boast an epoxy-coated cast-aluminum body for maximum durability and stability. The temperature range runs from 49 to 450C. The unit includes a 6ft cord with plug.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Braintree Scientific Optional Support Rod for Digital Hot Plate
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Optional Support Rod for Digital Hot Plate **Sold for research purposes only and not for human use**

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Research Products International Corp Digital Hot Plate Stirrer, 12x12" Aluminum Top
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Digital Hot Plate Stirrer, 12x12" Aluminum Top

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences SUPER-NUOVA™ Digital Stirring Hot Plate Ceramic Top, 220/240 V, 10.5" x 10.5" heating surface, 50 to 1200 RPM
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
These hot plates are ideal for cold rooms and can be used at 0-27°C with 80% relative humidity, in a non-condensing environment. Stir Trac technology offers improved slow speed stirring, consistent speed control and stronger magnetic coupling from 50 rpm to 1200 rpm. The integral ring stand holder accepts 1.3cm diameter support rod. A single knob design controls heating/stirring and goes up slowly when rotated slowly and faster when rotated faster. Adjustable 1 °C and 1 rpm increments. The RS232 port enables output of time count, temp set points, top surface/remote probe temp, stirring set point and actual speed to a printer or computer. Supplied with 6" type K probe, detachable cord, retention bracket that prevents cord from accidental removal, and a TFE-coated stir bar. Walk-away timer shuts off heating, stirring or both after a preset user-defined interval. Alkali/acid resistant white ceramic top.Heating surface: 10.5" x 10.5"RPM: 50 to 1200Amps: 5.7Wattage: 1365

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Corning Digital PC-420 Hot Plate/Stirrer, 220 V, 60-1150 RPM
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Pyroceram glass-ceramic stirring hot plates features a microprocessor with digital display that regulates heating and stirring. Consistent and repeatable temperature is maintained from 25 °C up to 550 °C and is adjustable in 5 °C increments. Display blinks until temp is reached and LED HOT TOP icon lights up when top plate is over 60°C and separate temp sensor provides power cutoff if unit overheats.
An optional external temp controller is available for inside the vessel and will shut off unit when is not in liquid. Stirring speed range is from 60-1150 RPM. Stronger, larger magnet improves stir bar coupling combined with automatic up speed adjustment minimizes decoupling. The two piece casting design deflects spills away from electronic and includes a built in mount for an optional 18" support rod. UL and cUL approved.
Heating surface: 10" x 10"
Range: 25-550°C
RPM: 60-1150
Weight: 11.5 lb
Footprint: 15.8 x 10.6"

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences SUPER-NUOVA™ Digital Stirrers Ceramic Top, 120 V, 50 to 1200 RPM, 7.25" x 7.25" heating surface
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
SuperNuova digital stirers with Stir Trac offers improved slow speed stirring, consisting speed control and stronger magnetic coupling from 50 rpm up to 1200 rpm. The seamlesss reflective white ceramic top enhances sample visibility and the rugged low-profile cast aluminum body provides stability and durability. The easy-to-read digital displays indicate rpm for stirring models, adjustable in 1 rpm increments. The user programmable preset buttons allow for up to four often-used stirring speeds to be recalled at the touch of a single button. Set points go up slowly when the knob is rotated slowly, faster as the knob is rotated faster. The knob then is locked out to avoid accidental changes. All models supplied with 2" x 3/8" dia TFE-coated stir bar, detachable cord and retention racket that prevents cord from accidentally removed.
RPM: 50 to 1200
Heating surface: 7.25" x 7.25"
Footprint: 8.2" x 13"
Height: 3.8"

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences SUPER-NUOVA™ Digital Stirring Hot Plate Aluminum Top, 220/240 V, 7.25" x 7.25" heating surface, 50 to 1200 RPM
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
These hot plates are ideal for cold rooms & can be used at 0-27°C w/ 80% relative humidity, in a non-condensing environment. Stir Trac technology offers improved slow speed stirring, consistent speed control & stronger magnetic coupling from 50 rpm to 1200 rpm. The integral ring stand holder accepts 1.3cm diameter support rod. A single knob design controls heating/stirring & goes up slowly when rotated slowly & faster when rotated faster. Adjustable 1 °C & 1 rpm increments. The RS232 port enables output of time count, temp set points, top surface/remote probe temp, stirring set point & actual speed to a printer or computer. Supplied w/ 6" type K probe, detachable cord, retention bracket that prevents cord from accidental removal, & a TFE-coated stir bar. Walk-away timer shuts off heating, stirring or both after a preset user-defined interval. Durablle aluminum top for uniform heat distribution.Heating surface: 7.25" x 7.25"RPM: 50 to 1200Amps: 3.0Wattage: 710

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences PC620 Hot Plate/Stirrer, 120 V, 60-1150 RPM
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Pyroceram glass-ceramic stirring hot plates features a microprocessor with digital display that regulates heating and stirring. Consistent and repeatable temperature is maintained from 25 °C up to 550 °C and is adjustable in 5 °C increments. Display blinks until temp is reached and LED HOT TOP icon lights up when top plate is over 60°C and separate temp sensor provides power cutoff if unit overheats.An optional external temp controller is available for inside the vessel and will shut off unit when is not in liquid. Stirring speed range is from 60-1150 RPM. Stronger, larger magnet improves stir bar coupling combined with automatic up speed adjustment minimizes decoupling. The two piece casting design deflects spills away from electronic and includes a built in mount for an optional 18" support rod. UL and cUL approved.Heating surface: 10" x 10"Range: 25-550°CRPM: 60-1150Weight: 11.5 lbFootprint: 15.8 x 10.6

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More